Twin AC Controller

Twin AC Controller
Twin AC Controller
Product Code : PROTOCOM - 1
Brand Name : MINILEC
Product Description

Twin AC Controller

Blessed and supported by the team of high skilled and talented personnel, our company is considered as one of the leading manufacturers and exporters of Twin AC Controller. Our comprehensive range is manufactured from high grade raw materials procured from trusted and reliable vendors of the industry. Manufactured as per market standards, our heavy duty Twin AC Controller is offered at industry leading prices. Appreciated for their compact design, impeccable performance and minimum maintenance features, these AC controllers are in a high demand in the global market.

Specifications


PROTOCOM - 1

Saves energy by alternatively using only one air conditioner (or both in case of temp rise) and that too only when it is required depending upon logic selected. Two Types of different operational logics can be selected with Protocom-1 through front Keys and display. These LOGICS are as follows.

During Logic  1 operation
Only one AC at a time will run for set time cycle in alternate mode. Changeover will take place only if

  • Cycle time is completed

  • Running AC is tripped due to Overload

  • Over Temp condition is present for more that 10 minutes.

If the room temperature keeps on rising even with the AC unit is in operation, it will energize OT alarm relay. It will stop running AC, ALARM LED will glow and switchover to another AC unit overriding present timing. Thus it also monitors and maintains the room temp.

During Logic  2 operation

One AC will be running as normal running AC for set time cycle. If temp rises above OT set point. second AC is switch on as stand-by running AC. This AC will be running until temp drops below OT-Hysteresis level (LIFO). In case, both AC are running and cycle time completes, none of the AC will be switch off or no change over will take place. However if temp drops below. OT-Hysteresis set point, first started AC will be made off and running AC will be considered as normal running AC (FIFO).

Functioning

Normal Cyclic Operation

After Power ON POWER LED indication glows steady. Display will start showing input AC voltage, AC1 & AC2 current and Room temp with scanning time of 5 sec. AC1will become ON and will remain ON for next set time cycle. After completion of timing cycle, it will be OFF and second AC will ON. Second AC will remain ON for next set time cycle. This operation will be repeated in cyclic mode. When AC is on, respective LED glows steady. Internal timer will retain timing cycle (with resolution of 1 Hr. ) in case of power failure with built in memory retention facility. Every time any AC will be made ON after ON delay of 2 Minutes.

Under Voltage & Over Voltage

The PROTOCOM-1 offers built-in protection against under voltage (170 VAC with auto reset gap of 6 VA C) & over voltage (270 VA C with 6 VA C auto reset gap) with 4 sec. trip time delay. Upon arising one of above condition running AC will switch OFF & 'ALARM' indication turns ON. Display shows 'uV' / 'oV' indication. Once condition gets cleared, same AC will be made ON.

Over Load

The PROTOCOM-1 protects the AC against over load condition of the set value. Running AC will switch OFF after O/L trip time delay. 'ALARM' LED will glow, display will show 'oL' indication & Alternative AC will be switch ON. Alternate AC will operate for remained time cycle & then again earlier AC will be switch ON.

Over Temp

The PROTOCOM-1 unit operates the AC by sensing the room temperature with the help of built-in temperature sensor. After power ON or during running of any AC, the ambient temp is monitored and if it is above set OT level for more than 10 minutes, then 'ALARM' LED turns on, also OT ALARM relay gets energized. Then running AC is switch OFF assuming that it is unable to lower the room temp below the set level. Alternative AC will switch ON. It will operate for remaining time cycle. After completion of time cycle other AC will be switch ON. 'OT ALARM' relay remain in energized condition till the ambient temp reduces below the hystersis level of OT set point. In case LOGIC - 2 is selected, another AC will be made ON as stand by running AC.

Fault Buzzer

After arriving of above any of fault condition Fault buzzer will be ON & will be retain for 1 Minute or till clearance of fault Condition (except OL fault) whichever is earlier.

Technical Specifications

  • System Supply : 240 V AC, +20%, 1 Ph

  • Frequency : 50 (60) Hz, +3%

  • Output Relay Contact : 1 NO + 1 NO + 1 NO

  • Output Contact Rating : 30 Amp @ 240 V AC (RLY 1 & RLY 2) 5 Amp (for RLY 3)

  • Current Setting : 8-16 Amp (Variable)

  • Power ON Delay : 2 mins, +0.5 min (Fixed)

  • Cyclic time Delay : 1 To 12 hours.

LED Indication

  • Power On: Green

  • Alarm: Red

  • AC 1 On : Green

  • AC 2 On: Green

Enclosure: Sheet metal fabricated and powder coated

Dimension (mm)

  • Overall (LxWxD): 141 x 193.9 x 72

  • Mounting (L x W): 117 x 169.5 

Weight: 1000 gms

Trip settings, time delay and resetting

Parameters

Under Voltage

Over Voltage

Over Load

Over Temperature

Trip Setting

170 + 3 VAC (Fixed)

270 + 3VAC (Fixed)

8-16 AMP (Settable by Keys & Display) (Default Set - 12 A)

20-40oC (Settable by Keys & Display) (Default Set - 30o A)

Hysteresis for Auto Reset

6 VAC + 3 VAC 6

6 VAC + 3 VAC

N. A.

1oC - 5oC0 (Default - 3o C)

Trip Time Delay

4 SEC. + 0.5 SEC.

4 SEC + 0.5SEC.

For 120% : 30 SEC+10SEC For 600% : 2SEC + 0.5SEC

10 Minutes

Message on Display

UV

OV

OL1 - For AC 1 OL2 - For AC 2

OT

Logic Setting

  • Logic 1: Single ac operation only in alternate mode (default set)

  • Logic 2: Single or both ac operation based on temp. rise in alternate mode.

Fault Buzzer: Auto reset type built in buzzer for UV, OV, OL & OT trip

Alarm time: 60sec. + 5 Sec

Setting Keys: 3 Nos of Front Keys

Applications

Suitable For Following Applications

  • Single Phase Twin AC unit control.

  • Energy Saving by optimal use of AC. Units.

  • BTS Exchange

  • ATM Machine


YASHPRABHA GROUP

Contact Us

( *represents compulsory fields )

Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.

Other Products in 'Industrial Automation' category


  • Contact Details
  • S.No.1073/1-2-3, At Post Pirangoot, Mutha Road, Tal. Mulshi,Pune - 412111, Maharashtra, India
  • Phone : +918268157371
  • Fax : 91-20-22922134/66524695/25432349

    Product Showcase
    YASHPRABHA GROUP All Rights Reserved.